Install
|
TOC |
 WARNING 
The regulator spring must be compressed to install the retainer plug. Personal injury can result. Wear face and eye protection.
|
NOTE: A counterbore plunger and orifice is unique to engines with a viscosity sensor. Low oil pressure will result if a solid plunger is used with a viscosity sensor.
Install the regulator plunger (3) and regulator spring (2).
Install and tighten the retainer plug (1).
Torque Value:
Rear Sump Oil Pan 75 n.m [55 ft-lb]
Torque Value:
Front Sump Oil Pan 122 n.m [90 ft-lb]
|

|
|
|
|
Last Modified: 23-Jan-2009
Published by Jack
Hello, I'm Jack, a diesel engine fan and a blogger. I write about how to fix and improve diesel engines, from cars to trucks to generators. I also review the newest models and innovations in the diesel market. If you are interested in learning more about diesel engines, check out my blog and leave your feedback.