Auxiliary Input/Output 2 Circuit Voltage Above Normal or Shorted to High Source
|
Overview
CODE | REASON | EFFECT |
Fault Code: 527 PID: S154 SPN: 702 FMI: 3 LAMP: Amber SRT: |
Auxiliary Input/Output 2 Circuit Voltage Above Normal or Shorted to High Source. High signal voltage or open circuit has been detected at the auxiliary input and output 2 circuit. |
None on performance |
Dual Output Signal
|
Circuit Description
The electronic control module (ECM) provides a signal to the OEM output control solenoid to turn the OEM supplied accessory on and off. The OEM output control circuit varies by OEM. Certain OEM’s may use a solenoid return that is wired to the ECM or may use a return that goes to engine block or chassis ground.
Component Location
The OEM out solenoid location varies by OEM. Refer to the appropriate OEM service literature to determine the location.
Shop Talk
The ECM monitors the voltage level on this circuit. When the ECM commands the OEM output signal low, it expects the voltage level to be approximately zero volts. If it detects a high voltage, this fault is recorded. If Fault Code 527 is still active after completing the following troubleshooting steps, consult the OEM service literature for procedures to check the OEM output device for an open circuit or short to ground. Possible causes of this fault include:
- Open circuit in the engine harness or OEM output control solenoid
- Short circuit to voltage source in the OEM harness
- Failed ECM.
Refer to Troubleshooting Fault Code t05-527