CM2150 Electronic Control System – 019-210   AMP VP44 Connector Series

Pin Replacement

TOC

The connector pins can not be repaired or replaced. The connector must be replaced as a unit.

Refer to the Connector Replacement step in this procedure for replacement instructions.

SMALL | MEDIUM | LARGE

Connector Replacement

TOC

This connector is used to connect the VP44 fuel pump to the ECM.

The pins in this connector can not be repaired or replaced. The connector must be replaced as a unit.

 
SMALL | MEDIUM | LARGE
   


Measure 178 mm [7 in] back from the face of the connector and remove the wiring harness protective cover.

SMALL | MEDIUM | LARGE
   


Before cutting the wires, measure and tag all of the wires.

Use wire crimping tool, Part Number 3822930, to cut the wires.

Cut wire A 165 mm [7 in] from the face of the connector.

Cut wire B 152 mm [6-½ in] from the face of the connector.

Cut wire C 140 mm [6 in] from the face of the connector.

Cut wire D 130 mm [5-½ in] from the face of the connector.

Cut wire E 117 mm [4-½ in] from the face of the connector.

Cut wire F 104 mm [4 in] from the face of the connector.

Cut wire G 91 mm [3-½ in] from the face of the connector.

SMALL | MEDIUM | LARGE
   


Use the wire crimping tool to remove 6 mm [¼ in] of insulation from all electrical wires.

SMALL | MEDIUM | LARGE
   


Before installing the new connector, perform a test fit to make sure the connector is keyed correctly.

Refer to the appropriate wiring repair kit in the service tools table in the front of Section 19 for the correct repair connector.

Refer to the wiring diagram in Section E for pin locations.

Install the pin repair wires and connector onto the bare wires of the harness and use the wire crimping tool to crimp each repair wire onto the harness.

SMALL | MEDIUM | LARGE
   


For added protection, wrap the wires with tape to complete the repair.

 