B5.9G, B5.9LPG – Troubleshooting and Repair Manual – 003-011   Rocker Lever Cover

Remove

TOC

15 mm

Remove the rocker lever covers.

SMALL | MEDIUM | LARGE

Clean

TOC

 WARNING 

Wear appropriate eye and face protection when using compressed air. Flying debris and dirt can cause bodily injury.

Clean rocker lever cover with a strong solution of detergent in hot water.

Dry with compressed air.

SMALL | MEDIUM | LARGE
   

Inspect for Reuse

TOC

Check the rocker lever cover(s) for cracks.

SMALL | MEDIUM | LARGE
   

Install

TOC

15 mm

Install rocker lever cover(s).

Tighten the capscrews.

Torque Value:  24  n.m  [18 ft-lb]

SMALL | MEDIUM | LARGE
Last Modified:  03-Apr-2002