Symptom Tree t072
| Cause | Correction |
|---|
|
Idle shutdown or PTO shutdown features are activated |
Turn OFF the keyswitch for 5 seconds. Turn ON the keyswitch and check fault lamp operation. Use INSITE™ electronic service tool to check Idle Shutdown and PTO parameters. |
![]() |
|
Fuel level is low in the tank |
Fill the supply tank. Refer to the OEM service manual. |
![]() |
|
Fuel inlet restriction |
Check for fuel inlet restriction. Refer to Procedure 006-020 (Fuel Inlet Restriction) in Section 6. |
![]() |
|
Air in fuel system |
Bleed the fuel system and correct source of the leak. Refer to Procedure 006-003 (Air in Fuel) in Section 6. |
![]() |
|
Fuel grade is not correct for the application or the fuel quality is poor |
Operate the engine from a tank of high-quality fuel. Refer to Fuel Recommendations and Specifications in the Operation and Maintenance Manual, Signature and ISX Engines, Bulletin 3666251. |
![]() |
|
Vehicle parasitics are excessive |
Check for transmission malfunctioning, cooling fan operation cycle time, and engine-driven units. Refer to the OEM service manual. |