Symptom Tree t083
This is symptom tree t083
| Cause | Correction |
|---|
|
Electronic fault codes active or high counts of inactive fault codes |
Refer to Section TF for fault code troubleshooting. |
![]() |
|
Verify the complaint |
Refer to the INSITE™ electronic service tool User’s Manual. |
![]() |
|
Diagnostic switch is in the ON position |
Turn off the diagnostic switch. |
![]() |
|
Diagnostic switch or circuit is malfunctioning |
Check the diagnostic switch and circuit. Refer to Procedures 019-027 and 019-028. |
![]() |
|
Fault code warning lamp circuit is malfunctioning |
Check the fault code warning lamp circuit. Refer to Procedure 019-047. |
![]() |
|
Fault code warning lamp is not correct |
Verify that the fault code warning lamp bulb is rated for 12 VDC and 200 mA. Refer to Procedure 019-046. |