Symptom Tree t084
| Cause | Correction |
|---|
|
Verify the complaint |
Refer to the INSITE™ electronic service tool User Manual. |
![]() |
|
Fault code warning lamps are burned out |
Check the warning lamps for voltage. Replace the bulbs if necessary. Refer to Procedure 019-047. |
![]() |
|
Fault code warning lamp circuit is malfunctioning |
Check the fault code warning lamp circuit. Refer to Procedure 019-047. |
![]() |
|
Battery voltage is low |
Inspect the batteries and the unswitched battery supply circuit. Refer to Procedure 019-087. |
![]() |
|
Diagnostic switch or circuit is malfunctioning |
Check the diagnostic switch and circuit. Refer to Procedures 019-027 and 019-028. |
![]() |
|
Keyswitch circuit is malfunctioning |
Check the vehicle, equipment, or vessel keyswitch circuit. Refer to Procedure 019-064. |
![]() |
|
Fault code warning lamp is not correct |
Verify that the fault code warning lamp bulb is rated for 12 VDC and 200 mA. Refer to Procedure 019-046. |