CM2150 Electronic Control System – FAULT CODE 124 (QSB3.3)

Intake Manifold 1 Pressure – Data Valid but Above Normal Operational Range – Moderately Severe Level


Overview

CODE REASON EFFECT
Fault Code: 124
PID: P102
FMI: 0/16
LAMP: Amber
SRT: 

Intake Manifold 1 Pressure Sensor Circuit – Data Valid but Above Normal Operational Range – Moderately Severe Level. Intake manifold pressure has exceeded the maximum limit for the given engine rating.

Engine power derate.

Intake Manifold Pressure/Temperature Circuit
SMALL | MEDIUM | LARGE

Circuit Description

The intake manifold pressure sensor is used by the electronic control module (ECM) to monitor the engine intake manifold pressure.

Component Location

Refer to Procedure 100-002 (Engine Diagrams) in Section F for a detailed component location view.

Shop Talk

Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM. Refer to Procedure 019-032 (ECM Calibration Code) in Section 19 in the corresponding Troubleshooting and Repair Manual for the engine being serviced.

This fault code becomes active when the intake manifold pressure exceeds the maximum pressure limit for a given engine rating.

Possible causes:

  • Malfunctioning turbocharger wastegate
  • Wastegate tampering
  • Wrong turbocharger part
  • Possible tampering of the fuel system or turbocharger system.

Refer to Troubleshooting Fault Code t05-124

Last Modified:  20-Jul-2010