SAE J1939 Data Link – Cannot Transmit Printable Version Overview CODE REASON EFFECT Fault Code: 426PID: S231SPN: 639FMI: 2LAMP: NoneSRT: SAE J1939 data link – cannot transmit. Communication between the…
Category: CM850 Electronic Control System – Troubleshooting and Repair Manual
Water-in-Fuel Indicator Data Valid but Above Normal Operational Range – Least Severe Level Printable Version Overview CODE REASON EFFECT Fault Code: 418PID: P097SPN: 97FMI: 0/15LAMP: Amber (Maintenance flashout)SRT: Water-in-Fuel Indicator…
Water-In-Fuel Indicator – Data Valid but Above Normal Operational Range – Least Severe Level Printable Version Overview CODE REASON EFFECT Fault Code: 418PID: P097SPN: 97FMI: 0/15LAMP: Amber (Maintenance flashout)SRT: Water-In-Fuel…
FAULT CODE 06-fc418Fault Code Path Selection Do you have an Automotive Application? Go to 06-fc418auto Do you have a Marine Application? Go to 06-fc418mar Last…
Engine Oil Rifle Pressure – Data Valid but Below Normal Operational Range – Most Severe Level Printable Version Overview CODE REASON EFFECT Fault Code: 415PID: P100SPN: 100FMI: 1/1LAMP: RedSRT: Engine…
Engine Oil Rifle Pressure – Data Valid but Below Normal Operational Range – Most Severe Level Printable Version Overview CODE REASON EFFECT Fault Code: 415PID: P100SPN: 100FMI: 1/1LAMP: RedSRT: Engine…
FAULT CODE 415Fault Code Path Selection Does the engine have an Oil Pressure Sensor? Go to 06-fc415sn Does the engine have an Oil Pressure Switch?…
SAE J1587/J1922 Data Link – Can Not Transmit Printable Version Overview CODE REASON EFFECT Fault Code: 412PID: S250SPN: 608FMI: 2LAMP: NoneSRT: SAE J1587/J1922 data link – can not transmit. Communication…
Accelerator Pedal or Lever Position Sensor Supply Voltage Circuit – Voltage Above Normal or Shorted to High Source Printable Version Overview CODE REASON EFFECT Fault…
Sensor Supply Voltage number 1 Circuit – Voltage Above Normal or Shorted to High Source Printable Version Overview CODE REASON EFFECT Fault Code: 386PID: S212SPN: 1079FMI: 3/3LAMP: AmberSRT: Sensor Supply…