| ICON™ Idle Speed (Adjustable) |
|
| – Integrated and Aftermarket, ICON™ Idle Control Module Revision Level 11, 13 and 14 |
|
| – Low nominal (rpm) |
850 |
| – High nominal (rpm) |
1000 |
– Aftermarket and OEM, ICON™
Idle Control Module Revision Level 15, 16 and 18 |
|
| – Low nominal (rpm) |
800 |
| – High nominal (rpm) |
900 |
| ICON™ Minimum Idle Speed (rpm) |
650 |
| ICON™ Maximum Idle Speed (rpm) |
1400 |
| ICON™ Minimum Run Time |
|
| – Integrated and Aftermarket, ICON™ Idle Control Module Revision Level 11, 13 and 14 |
5 minutes |
| – Aftermarket and OEM, ICON™ Idle Control Module Revision Level 15, 16 and 18 |
1 minute |
| Engine Oil Temperature |
|
| – Minimum (Engine Starts) |
16°C [60°F] |
| – Maximum (Required before engine shutdown) |
49°C [120°F] |
| Integrated ICON™ System |
|
| – Battery Voltage |
|
| – Minimum (Engine Starts) |
12.2V |
| – Minimum Run Time to charge batteries |
120 minutes |
| – Maximum (Shutoff Parameter Required) |
13.0 |
| – Mandatory Shutdown |
|
| – 1. |
5 minutes (adjustable to 24 hours) |
| – 2. |
15 minutes |
| Aftermarket ICON™ Idle Control Module Revision Level 11 and 13 |
|
| – Battery Voltage |
|
| – Minimum (Engine Starts) |
12.2V |
| – Minimum Run Time to charge batteries |
30 minutes |
| – Maximum (Shutoff Parameter Required) |
13.6 |
| – Mandatory Shutdown |
|
| – 1. |
5 minutes |
| – 2. |
15 minutes |
| Aftermarket ICON™ Idle Control Module Revision Level 14 |
|
| – Battery Voltage |
|
| – Minimum (Engine Starts) |
12.3V |
| – Minimum Run Time to charge batteries |
60 minutes |
| – Maximum (Shutoff Parameter Required) |
13.0V |
| – Mandatory Shutdown |
|
| – 1. |
5 minutes (adjustable to 18 hours) |
| – 2. |
15 minutes |
| Aftermarket ICON™ Idle Control Module Revision Level 15, 16 and 18 |
|
| – Battery Voltage |
|
| – Minimum (Engine Starts) |
12.3V |
| – Minimum Run Time to charge batteries |
60 minutes |
| – Maximum (Shutoff Parameter Required) |
13.0V |
| – Mandatory Shutdown Revision Level 15 |
|
| – 1. |
10 minutes (adjustable to 20 minutes) |
| – 2. |
10 minutes |
| – Mandatory Shutdown Revision Level 16 |
|
| – 1. |
5 minutes (adjustable to 20 minutes) |
| – 2. |
5 minutes |
| – Mandatory Shutdown Revision Level 18 |
|
| – 1. |
5 minutes with vehicle speed = 0 and park brake ON |
| – 2. |
15 minutes with vehicle speed = 0 and park brake OFF |
| Default Trim Settings |
|
| – Extreme Hot |
|
| – Thermostat, Revision Level 01 and 02 |
100°F |
| – Thermostat, Revision Level 03 |
110°F |
| – Thermostat, Revision Level 04 and 05 |
90°F |
| – Extreme Cold |
|
| – Thermostat, Revision Level 01, 02 and 03 |
0°F |
| – Thermostat, Revision Level 04 and 05 |
20°F |
| – Auto Heat |
|
| – Thermostat, Revision Level 01 and 02 |
75°F |
| – Thermostat, Revision Level 03, 04 and 05 |
69°F |
| – Auto Cool |
|
| – Thermostat, Revision Level 01 and 02 |
68°F |
| – Thermostat, Revision Level 03, 04 and 05 |
70°F |
| – Disable Heat |
80°F |
| – Disable Cool |
60°F |
| – Response to E3 Fault |
Enabled |
| – Alarm in Cab Comfort Mode1 |
Enabled |
| – Temperature Scale |
Fahrenheit |
| – Short Idle Enable1 |
Disabled |
| – Prelube Enable1 |
Disabled |
| – Reset to Defaults |
N/A |
| – Automatic E3 Shutdown |
Enabled |
| – Weekend Timer |
Enabled |
| – Narrow Temperature Setting |
Disabled |