ICON Idle Control System – 018-025   ICON™ System

Table of Contents

General Specifications

General Specifications

TOC

ICON™ Idle Speed (Adjustable)   
     – Integrated and Aftermarket, ICON™ Idle Control Module Revision Level 11, 13 and 14   
          – Low nominal (rpm)  850 
          – High nominal (rpm)  1000 
     – Aftermarket and OEM, ICON™
Idle Control Module Revision Level 15, 16 and 18 
 
          – Low nominal (rpm)  800 
          – High nominal (rpm)  900 
ICON™ Minimum Idle Speed (rpm)  650 
ICON™ Maximum Idle Speed (rpm)  1400 
ICON™ Minimum Run Time   
     – Integrated and Aftermarket, ICON™ Idle Control Module Revision Level 11, 13 and 14  5 minutes 
     – Aftermarket and OEM, ICON™ Idle Control Module Revision Level 15, 16 and 18  1 minute 
Engine Oil Temperature   
     – Minimum (Engine Starts)  16°C [60°F] 
     – Maximum (Required before engine shutdown)  49°C [120°F] 
Integrated ICON™ System   
     – Battery Voltage   
          – Minimum (Engine Starts)  12.2V 
          – Minimum Run Time to charge batteries  120 minutes 
          – Maximum (Shutoff Parameter Required)  13.0 
     – Mandatory Shutdown   
          – 1.  5 minutes (adjustable to 24 hours) 
          – 2.  15 minutes 
Aftermarket ICON™ Idle Control Module Revision Level 11 and 13   
     – Battery Voltage   
          – Minimum (Engine Starts)  12.2V 
          – Minimum Run Time to charge batteries  30 minutes 
          – Maximum (Shutoff Parameter Required)  13.6 
     – Mandatory Shutdown   
          – 1.  5 minutes 
          – 2.  15 minutes 
Aftermarket ICON™ Idle Control Module Revision Level 14   
     – Battery Voltage   
          – Minimum (Engine Starts)  12.3V 
          – Minimum Run Time to charge batteries  60 minutes 
          – Maximum (Shutoff Parameter Required)  13.0V 
     – Mandatory Shutdown   
          – 1.  5 minutes (adjustable to 18 hours) 
          – 2.  15 minutes 
Aftermarket ICON™ Idle Control Module Revision Level 15, 16 and 18   
     – Battery Voltage   
          – Minimum (Engine Starts)  12.3V 
          – Minimum Run Time to charge batteries  60 minutes 
          – Maximum (Shutoff Parameter Required)  13.0V 
     – Mandatory Shutdown Revision Level 15   
          – 1.  10 minutes (adjustable to 20 minutes) 
          – 2.  10 minutes 
     – Mandatory Shutdown Revision Level 16   
          – 1.  5 minutes (adjustable to 20 minutes) 
          – 2.  5 minutes 
     – Mandatory Shutdown Revision Level 18   
          – 1.  5 minutes with vehicle speed = 0 and park brake ON 
          – 2.  15 minutes with vehicle speed = 0 and park brake OFF 
Default Trim Settings   
     – Extreme Hot   
          – Thermostat, Revision Level 01 and 02  100°F 
          – Thermostat, Revision Level 03  110°F 
          – Thermostat, Revision Level 04 and 05  90°F 
     – Extreme Cold   
          – Thermostat, Revision Level 01, 02 and 03  0°F 
          – Thermostat, Revision Level 04 and 05  20°F 
     – Auto Heat   
          – Thermostat, Revision Level 01 and 02  75°F 
          – Thermostat, Revision Level 03, 04 and 05  69°F 
     – Auto Cool   
          – Thermostat, Revision Level 01 and 02  68°F 
          – Thermostat, Revision Level 03, 04 and 05  70°F 
     – Disable Heat  80°F 
     – Disable Cool  60°F 
     – Response to E3 Fault  Enabled 
     – Alarm in Cab Comfort Mode1  Enabled 
     – Temperature Scale  Fahrenheit 
     – Short Idle Enable1  Disabled 
     – Prelube Enable1  Disabled 
     – Reset to Defaults  N/A 
     – Automatic E3 Shutdown  Enabled 
     – Weekend Timer  Enabled 
     – Narrow Temperature Setting  Disabled 
  1. These trims are not adjustable in Revision Level 04 or 05 thermostats.

Last Modified:  25-Oct-2004