ECM – Warning Internal Hardware Failure
|
Overview
| CODE | REASON | EFFECT |
| Fault Code: 343 PID: 254 SPN: 629 FMI: 12 LAMP: Yellow SRT: |
Internal ECM error. |
Engine possibly will not start or run. |
|
ECM |
![]() |
Circuit Description
The electronic control module (ECM) is a computer that is responsible for engine control, diagnostics, and user features.
Component Location
The ECM is located on the side of the engine, next to the ignition control module (ICM).
Shop Talk
This fault code can only be caused by an internal ECM problem. Repairs to the ECM are not possible.
Cautions and Warnings
CAUTION ![]() To reduce the possibility of damaging a new ECM, all other active fault codes must be investigated prior to replacing the ECM. |
Troubleshooting Steps
| STEPS | SPECIFICATIONS | |
|---|---|---|
| STEP 1. | Check the ECM. | |
| STEP 1A. Check for fault codes. | Fault Code 343 active? | |
| STEP 1B. Check the power supply. | Constant +12 VDC power supply to the ECM? | |
| STEP 1C. Check ECM for a short circuit to ground. | More than 100k ohms? | |
| STEP 1D. Recalibrate the ECM. | ECM recalibrated successfully? | |
| STEP 2. | Clear the fault codes. | |
| STEP 2A. Disable the fault code. | Fault Code 343 inactive? | |
| STEP 2B. Clear the inactive fault codes. | All fault codes cleared? | |
Guided Step 1 – Check the ECM.
| Guided Step 1A – Check for fault codes. | |
|---|---|
Conditions
Action
|
|
|
Fault Code 343 active? |
|
| YES | NO |
| No Repair | No Repair |
| Guided Step 1B – Check the power supply. | |
|---|---|
Conditions
Action
|
|
|
Constant +12 VDC power supply to the ECM? |
|
| YES | NO |
| No Repair |
Intermittent power supply to the 31-pin OEM connector. Refer to the OEM service manual. |
| Guided Step 1C – Check ECM for a short circuit to ground. | |
|---|---|
Conditions
Action
|
|
|
More than 100k ohms? |
|
| YES | NO |
| No Repair |
Replace the ECM. Call for pre-authorization. Refer to Procedure 019-031. |
| Guided Step 1D – Recalibrate the ECM. | |
|---|---|
Conditions
Action
|
|
|
ECM recalibrated successfully? |
|
| YES | NO |
| No Repair |
Active fault codes present. Replace the ECM. Call for pre-authorization. Refer to Procedure 019-031. |
Guided Step 2 – Clear the fault codes.
| Guided Step 2A – Disable the fault code. | |
|---|---|
Conditions
Action
|
|
|
Fault Code 343 inactive? |
|
| YES | NO |
| No Repair |
Troubleshooting procedures need to be repeated from the beginning. |
| Guided Step 2B – Clear the inactive fault codes. | |
|---|---|
Conditions
Action
|
|
|
All fault codes cleared? |
|
| YES | NO |
| No Repair |
Troubleshoot any remaining active fault codes. |
|
Repair complete
|
Appropriate troubleshooting charts
|

CAUTION