Preparatory Steps
TOC
Remove or disconnect the following:
Engine wiring harness from the lift pump.
EGR differential pressure sensor tubes. Refer to Procedure 011-026 in the Signature, ISX and QSX15 Service Manual, Bulletin 3666239 .
EGR differential pressure sensor. Refer to Procedure 019-370 .
EGR differential pressure sensor mounting adapter.
Next
Remove
TOC
NOTE : The lift pump is bolted to a mounting plate and must not be removed from the mounting plate.
Remove the four capscrews.
Remove the lift pump.
Previous Next
Clean and Inspect for Reuse
TOC
Clean the mounting surfaces.
Inspect the lift pump mounting plate for leaks, cracks or damage. If cracks or damage are found, replace the lift pump.
Previous Next
Install
TOC
Install the lift pump and four capscrews.
Tighten the capscrews.
Torque Value: 18 n.m [14 ft-lb]
Previous Next
Finishing Steps
TOC
Install or connect the following:
EGR differential pressure sensor mounting adapter.
EGR differential pressure sensor. Refer to Procedure 019-370 .
EGR differential pressure sensor tubes. Refer to Procedure 011-026 in the Signature, ISX and QSX15 Service Manual, Bulletin 3666239 .
Engine wiring harness from the lift pump.
Turn the keyswitch to the ON position and verify the fuel pump is operating.
Operate the engine and check for leaks.
Previous
Last Modified: 20-Feb-2006
Published by Jack
Hello, I'm Jack, a diesel engine fan and a blogger. I write about how to fix and improve diesel engines, from cars to trucks to generators. I also review the newest models and innovations in the diesel market. If you are interested in learning more about diesel engines, check out my blog and leave your feedback.