CM2150 Electronic Control System – FAULT CODE 292 (QSB3.3)

Auxiliary Temperature Sensor Input 1 – Special Instructions.


Overview

CODE REASON EFFECT
Fault Code: 292
PID: P441
SPN: 441
FMI: 14
LAMP: Red
SRT: 

Auxiliary Temperature Sensor Input 1 – Special Instructions.

Possible engine power derate.

OEM Temperature/Pressure Sensor Circuit
SMALL | MEDIUM | LARGE

Circuit Description

The original equipment manufacturer (OEM) has the option of wiring a temperature sensor input to the Cummins ECM. A specific calibration is then created to recognize this temperature sensor input. This fault code is activated when the pressure or temperature input from the OEM sensor exceeds the engine protection limit defined by the OEM. Depending on OEM requirements, an Engine Protection derate may be associated with this fault code.

Component Location

The OEM temperature sensor input will vary depending on application. Refer to the OEM troubleshooting manual for sensor location.

Shop Talk

Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM. Refer to Procedure 019-032 (ECM Calibration Code) in Section 19 in the corresponding Troubleshooting and Repair Manual for the engine being serviced.

This fault code is activated when the temperature input from the OEM sensor exceeds the engine protection limit defined by the OEM. An engine power derate is possible depending on the OEM application.

Refer to Troubleshooting Fault Code t05-292

Last Modified:  20-Jul-2010