CM2150 Electronic Control System – FAULT CODE 293 (QSB3.3)

Auxiliary Temperature Sensor Input 1 Circuit – Voltage Above Normal or Shorted to High Source


Overview

CODE REASON EFFECT
Fault Code: 293
PID: P441
SPN: 441
FMI: 3
LAMP: Amber
SRT: 

Auxiliary Temperature Sensor Input 1 Circuit – Voltage Above Normal or Shorted to High Source. High signal voltage or open circuit detected at the OEM auxiliary temperature circuit.

None on performance.

Auxiliary Temperature Sensor Input 1 Circuit
SMALL | MEDIUM | LARGE

Circuit Description

The original equipment manufacturer (OEM) has the option of wiring a temperature sensor input to the Cummins electronic control module (ECM). A specific calibration is then created to recognize this temperature sensor input.

Component Location

The OEM temperature sensor input will vary depending on application. Refer to the OEM troubleshooting and repair manual for sensor location.

Shop Talk

Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM. Refer to Procedure 019-032 (ECM Calibration Code) in Section 19 in the corresponding Troubleshooting and Repair Manual for the engine being serviced.

Possible causes of this fault code include:

  • Open return circuit in the harness, connectors, or sensor
  • Open signal circuit or shorted to a voltage source.

Refer to Troubleshooting Fault Code t05-293

Last Modified:  20-Jul-2010