M11 Industrial Operation and Maintenance – Engine Will Not Shut Off

Symptom Tree  

Keyswitch circuit is malfunctioning

Check the vehicle, equipment, or vessel keyswitch circuit. Refer to the OEM service manual.

 

Engine is running on fumes drawn into the air intake

Check the air intake ducts. Locate and isolate the source of the fumes. Repair as necessary. Refer to the OEM service manual.

 
Contact a Cummins Authorized Repair Facility