M11 Series – Service Manual – 006-020   Fuel Inlet Restriction

Table of Contents

Measure

Measure

TOC

Remove the fuel supply hose to the gear pump and install the manometer, Part No. ST-1111-3. Use the appropriate hose adapter for the specific engine as described in the Service Tools list.

NOTE: If the gear pump inlet fitting has a Compuchek® fitting, the manometer can be installed there.

SMALL | MEDIUM | LARGE


Hold the manometer at the same level as the gear pump connection.

 
SMALL | MEDIUM | LARGE
   


Operate the engine at rated speed and

no load.

Observe the reading on the manometer.

Fuel Inlet Restriction
CELECT™ and CELECT™
Plus
mm-hg in-hg
Clean Filter   152 MAX 6
Dirty Fiter   254 MAX 10
Fuel Inlet Restriction — STC
mm-hg in-hg
Clean Filter   102 MAX 4
Dirty Fiter   204 MAX 8

Correct the restriction or replace the fuel filter.

NOTE: The cooling plate on CELECT™ and CELECT™ Plus engines has about 25.4 mm Hg [1 in Hg] restriction.

 
SMALL | MEDIUM | LARGE
   


Cooling Plate Inspection

NOTE: This action applies to CELECT™ and CELECT™ Plus engines only.

Inspect the cooling plate for restriction, porosity, and leakage. To inspect for porosity and leakage, visually examine the cooling plate for fuel leaks. If any leaks are found replace the cooling plate. Refer to Procedure

006-006.

SMALL | MEDIUM | LARGE
   


NOTE: This action applies to CELECT™ and CELECT™ Plus engines only.

Install the mercury manometer, Part No. ST-1111-3, line to a tee fitting. Connect one on and off valve at either side of the tee. Attach the hose and appropriate fittings.

SMALL | MEDIUM | LARGE
   


NOTE: This action applies to CELECT™ and CELECT™ Plus engines only.

Remove the fuel line from the rear of the cooling plate (fuel in). Install one side of the manometer hose into the fuel line. Connect the line to the cooling plate. Connect the other side of the manometer hose into the line from the front of the cooling plate (fuel out). Make sure both valves are closed.

SMALL | MEDIUM | LARGE
   


NOTE: This action applies to CELECT™ and CELECT™ Plus engines only.

Start the engine and operate it at rated rpm and no load.

 
SMALL | MEDIUM | LARGE
   


NOTE: This action applies to CELECT™ and CELECT™ Plus engines only.

Open the valve on the inlet side of the manometer and read the vacuum on the manometer. Record the vacuum reading.

SMALL | MEDIUM | LARGE
   


NOTE: This action applies to CELECT™ and CELECT™ Plus engines only.

Close the valve on the inlet side of the manometer. Open the valve on the outlet side of the manometer. Record the vacuum reading on the manometer.

Cooling Plate Restriction
mm-hg in-hg
25 MAX 1

If the restriction is greater than the value given, clean or replace the cooling plate.

SMALL | MEDIUM | LARGE
Last Modified:  07-May-2003