Centinel System – Repair Manual – 001-033   Gear Housing, Front

View Related Topic


Table of Contents

Remove

Remove

TOC

 WARNING 

The component weighs 23 kg [50 lb] or more. To reduce the possibility of injury, use a hoist or get assistance to lift the component.

Remove two capscrews and install two guides.

SMALL | MEDIUM | LARGE


Remove the remaining 18 capscrews.

Remove the housing and gasket.

Discard the gasket.

Remove the guide studs.

SMALL | MEDIUM | LARGE