Centinel System – Repair Manual – 010-120   Turbocharger, Variable Geometry Actuator Air Supply Line

Table of Contents

Remove

Remove

TOC

 CAUTION 

The turbocharger control valve is very sensitive to contamination. Failure to prevent contamination from entering the turbocharger control valve air lines will cause damage to the turbocharger control valve.

Make sure the keyswitch is in the OFF position.

Disconnect the air line at the turbocharger actuator.

Mask the end of the air line and turbocharger actuator to prevent contamination.

SMALL | MEDIUM | LARGE


Remove the p-clip at the thermostat housing.

Disconnect the air line from the turbocharger control valve.

Mask the end of the air line and turbocharger control valve to prevent contamination.

Remove the turbocharger control valve air line.

SMALL | MEDIUM | LARGE
Last Modified:  19-Apr-2005