Electronic Control System Signature, ISX and QSX15 Engines – FAULT CODE 386

Sensor Voltage Supply


Overview

CODE REASON EFFECT
Fault Code: 386
PID: S232
SPN: 1079
FMI: 3/3
LAMP: Yellow
SRT: 

High voltage detected on the electronic control module (ECM) voltage supply wire to the sensors (VSEN1 supply).

Engine is derated to no-air setting.

Sensor Voltage Supply Circuit
SMALL | MEDIUM | LARGE

Circuit Description

The electronic control module (ECM) supplies each of these sensors with positive (+) 5 VDC. If the supply wire to any sensor is damaged, the sensor will not work correctly.

Component Location

There are three components involved in the sensor voltage supply: Intake manifold pressure/temperature sensor, ambient air pressure/temperature sensor, and the fuel pressure sensor. See Section E for component location.

Shop Talk

High voltage on the sensor (+) 5-VDC supply wire will be caused by a short circuit to battery of the supply wire or a short circuit between an actuator wire and the supply wire.

Refer to Troubleshooting Fault Code t05-386.