ISB/ISBe Series Engines – FAULT CODE 431

Idle Validation Switch Circuit


Overview

CODE REASON EFFECT
Fault Code: 431
PID: S230
SPN: 558
FMI: 2
LAMP: Yellow
SRT: 

Idle validation signals indicate no voltage detected simultaneously on both idle and off-idle pins.

No effect on performance but loss of idle validation.

Idle Validation Switch Circuit
SMALL | MEDIUM | LARGE

Circuit Description

The idle validation switch is used by the electronic control module (ECM) to indicate when the accelerator pedal is released (on-idle) or depressed (off-idle). The switch is adjusted by the accelerator pedal manufacturers to switch from on-idle to off-idle at the correct accelerator pedal position.

Component Location

The idle validation switch is located on the accelerator pedal assembly.

Shop Talk

This fault code is usually caused by a loose connection, uncalibrated accelerator pedal, or miswired idle validation switch.

A bad ground on pin A of the idle validation switch can also cause this fault.

Refer to Troubleshooting Fault Code t05-431

Last Modified:  26-Oct-2010