CM870 and ISX Engines – 019-080   Remote PTO Switch

General Information

TOC

A remote PTO switch is available for applications where PTO operation control is desired away from the operator controls.

SMALL | MEDIUM | LARGE


The remote PTO switch circuit consists of the remote PTO switch, remote PTO switch signal wire and a remote PTO switch return wire.

 
SMALL | MEDIUM | LARGE
   

Resistance Check

TOC

Locate the remote PTO switch.

Remove and tag the two connectors from the terminals on the switch.

Touch the multimeter probes to the terminals on the switch.

SMALL | MEDIUM | LARGE
   


Move the switch to the OFF position and measure the resistance. The multimeter must show an open circuit (100k ohms or more). If the circuit is not open, the switch has failed.

Replace the switch. Refer to the OEM troubleshooting and repair manual for the replacement procedures.

SMALL | MEDIUM | LARGE
   


Move the switch to the ON position and measure the resistance. The multimeter must show a closed circuit (10 ohms or less). If the circuit is not closed, the switch has failed.

Replace the switch. Refer to the OEM troubleshooting and repair manual for the replacement procedures.

If the resistance value is correct, the switch must still be checked for a short circuit to ground.

SMALL | MEDIUM | LARGE
   

Check for Short Circuit to Ground

TOC

Touch one of the multimeter probes to one of the switch terminals. Touch the other probe to chassis ground. Move the switch to the ON position and measure the resistance. The multimeter must show an open circuit (100k ohms or more). If the circuit is not open, the switch has failed. Replace the switch. Refer to the OEM troubleshooting and repair manual for replacement procedures. If the switch passes all of the previous checks, the circuit must be checked for an open circuit, a short circuit to ground, a short circuit from pin to pin, and a short circuit to an external voltage source.

SMALL | MEDIUM | LARGE
Last Modified:  14-Mar-2002