CM870 and ISX Engines – FAULT CODE 352

Sensor Supply Voltage Number 1 Circuit


Overview

CODE REASON EFFECT
Fault Code: 352
PID: S232
SPN: 1079
FMI: 4/4
LAMP: Amber
SRT: 

Sensor Supply Voltage Number 1 Circuit – shorted low. Low voltage detected at sensor supply Number 1 circuit.

Engine will run derated.

Sensor Supply Voltage Number 1 Circuit
SMALL | MEDIUM | LARGE

Circuit Description

The sensor supply voltage Number 1 of the electronic control module
(ECM) provides (+) 5 volt supply for the barometric pressure sensor, engine oil pressure sensor, and fuel pump pressure sensor on the engine harness. This +5 volt supply also powers two optional OEM devices. The two devices are digital vehicle speed sensor and remote accelerator sensor.

Component Location

The sensor supply Number 1 is located in the ECM. The supply voltage is spliced off in the engine and OEM harness to each sensor it supports.

Shop Talk

Low voltage on the (+) 5 volt supply line can be caused by a short circuit to ground in a supply line, a short circuit between a supply line and a return line, a failed sensor, or a failed ECM power supply.

Refer to Troubleshooting Fault Code t05-352

Last Modified:  01-Sep-2010