Low Pressure Dry Processed Natural Gas (Low Heat Value) |
950 BTU/ft3 |
Low Pressure Dry Processed Natural Gas (High Heat Value) |
1035 BTU/ft3 |
Recommended Gas Filter Capability (Particle Size) –
Minimum |
10 Microns |
Running Pressure To Engine Mounted Regulator – Minimum |
254 mm H2O [10 in H2O] |
Running Pressure To Engine Mounted Regulator – Maximum |
508 mm H2O [20 in H2O] |
Pressure from the Engine Mounted Regulator – Minimum |
101 mm H2O [4 in H2O] |
Pressure from the Engine Mounted Regulator – Maximum |
152 mm H2O [6 in H2O] |
NOTE: Specifications assume dry processed natural gas with liquids removed. Gas composition is primarily methane, with a small percentage of ethane, that is 950 BTU cu. ft. low heat value.
Ignition Timing and Exhaust Oxygen Content |
Engine |
*Degrees Before TDC |
**Excess 02% (Standby – Maximum) |
**Excess 02% (Prime – Continuous) |
G5.9 |
26 |
0.5 |
0.5 |
GTA5.9 |
26 |
3.0 |
5.8 |
G8.3 |
26 |
0.5 |
2.6 |
GTA8.3 |
30 |
6.1 |
6.1 |
G855 |
24 |
0.5 |
0.5 |
GTA855 |
24 |
4.2 |
4.2 |
GTA14HC |
20 |
4.0 |
4.0 |
GTA14LC |
24 |
4.0 |
4.0 |
KTA19GC |
20 |
6.0 |
6.0 |
KTA38GC (Standard) |
35 |
8.6 |
8.6 |
KTA38GC (Catalyst) |
35 |
0.3 |
0.3 |
GTA28 |
24 |
4.0 |
4.0 |
GTA38 |
20 |
5.0 |
5.0 |
GTA50 |
20 |
4.0 |
4.0 |
NOTE: *KTA19 at 1524 m [5000 ft] without derates, all other engines at 1219 m [4000 ft] without derates.
NOTE: **Without a Catalytic Converter.
Engine – Application Derates: Altitude, Ambient Air and Aftercooler Water Temperature |
Engine(s) |
Application(s) |
Power Rating |
Compression Ratio |
*Maximum Altitude w/o Derate |
**Maximum Ambient – Intake Manifold Temperature w/o Derate |
Maximum Aftercooler Water Temperature |
G5.9, G8.3, G855 |
Industrial, Generator |
Maximum, Standby |
N/A |
152 m [500 ft] |
29°C [85°F] |
N/A |
G5.9, G8.3, G855 |
Industrial, Generator |
Continuous, Prime |
N/A |
457 m [1500 ft] |
38°C [100°F] |
N/A |
GTA5.9, GTA8.3 |
Industrial, Generator |
Maximum, Standby |
High Compression Ratio |
914 m [3000 ft] |
52°C [125°F] |
N/A |
GTA5.9, GTA8.3 |
Industrial, Generator |
Maximum, Standby |
Low Compression Ratio |
914 m [3000 ft] |
60°C [140°F] |
N/A |
GTA5.9, GTA8.3 |
Industrial, Generator |
Continuous, Prime |
High Compression Ratio |
1524 m [5000 ft] |
52°C [125°F] |
N/A |
GTA5.9, GTA8.3 |
Industrial, Generator |
Continuous, Prime |
Low Compression Ratio |
1524 m [5000 ft] |
60°C [140°F] |
N/A |
GTA14, GTA28 |
Industrial |
Maximum |
N/A |
914 m [3000 ft] |
52°C [125°F] |
N/A |
GTA14, GTA28 |
Industrial |
Continuous |
N/A |
1524 m [5000 ft] |
52°C [125°F] |
N/A |
GTA14 |
Generator |
Standby |
N/A |
914 m [3000 ft] |
52°C [125°F] |
N/A |
GTA14 |
Generator |
Continuous, Prime |
N/A |
1524 m [5000 ft] |
52°C [125°F] |
N/A |
GTA19, GTA28 |
Generator |
Standby |
N/A |
914 m [3000 ft] |
38°C [100°F] |
N/A |
GTA19, GTA28 |
Generator |
Continuous, Prime |
N/A |
1524 m [5000 ft] |
38°C [100°F] |
N/A |
GTA19 |
Industrial |
Maximum |
N/A |
914 m [3000 ft] |
38°C [100°F] |
N/A |
GTA19 |
Industrial |
Continuous |
N/A |
1524 m [5000 ft] |
38°C [100°F] |
N/A |
KTA38GC, KTA19GC |
Industrial |
Continuous |
N/A |
1524 m [5000 ft] |
38°C [100°F] |
54°C [130°F] |
GTA38, GTA50 |
Generator |
G1 or G2 Standby |
N/A |
914 m [3000 ft] |
63°C [145°F] |
54°C [130°F] |
GTA38, GTA50 |
Generator |
G1 or G2 Prime |
N/A |
1524 m [5000 ft] |
63°C [145°F] |
54°C [130°F] |
GTA50 |
Generator |
G3 Standby |
N/A |
305 m [1000 ft] |
52°C [125°F] |
43°C [110°F] |
GTA50 |
Generator |
G3 Prime |
N/A |
914 m [3000 ft] |
52°C [125°F] |
43°C [110°F] |
NOTE: *Derate is 4% per 305 m [1000 ft] above maximum.
NOTE: **Derate is 1% per -12°C [10°F] above maximum.
|