CM850 Electronic Control System – FAULT CODE 1713

Catalyst Tank Heater Circuit – Data Valid But Above Normal Operating Range – Moderately Severe Level


Overview

CODE REASON EFFECT
Fault Code: 1713
PID: 
SPN: 3363
FMI: 0/16
LAMP: Amber
SRT: 

Catalyst Tank Heater Circuit – Data Valid But Above Normal Operating Range – Moderately Severe Level. The catalyst tank heater is continuously in the on position.

None on performance.

Circuit: Catalyst Tank Heater Relay
SMALL | MEDIUM | LARGE

Circuit Description

The catalyst tank heater keeps the catalyst solution from freezing in the catalyst tank. The catalyst heater element is powered through the catalyst tank heater relay. The tank heater is activated once the temperature recorded by the OEM tank temperature/level sensor is below a temperature threshold.

Component Location

The catalyst tank heater is located in the catalyst tank. The location of the catalyst tank heater relays will vary by OEM.

Shop Talk

This fault code is triggered when the catalyst tank heater is determined to be in the on position when the engine ECM is commanding the heater to be in the off position. To determin if the temperature sensors are reading a sensible value, they can be compared to each other at keyswitch ON, after an 8-hour period with the engine not running. At this point, the engine TMAP sensor should display a similar temperature to the tank. For example: ambient air temperature.

Possible causes of this fault code include:

  • Damaged catalyst solution OEM tank temperature/level sensor
  • Damaged catalyst solution tank heater relay
  • Failed ECM that is commanding the heater on continuously.

On-Board Diagnostics (OBD) Information:

  • The ECM illuminates the appropriate amber or red fault code lamp when the diagnostic runs and fails
  • The ECM turns OFF the appropriate fault lamp when the diagnostic runs and passes.

Refer to Troubleshooting Fault Code t05-1713