CM850 Electronic Control System – FAULT CODE 293

Auxiliary Temperature Sensor Input 1 – Voltage Above Normal, or Shorted to High Source


Overview

CODE REASON EFFECT
Fault Code: 293
PID: P441
SPN: 441
FMI: 3
LAMP: Amber
SRT: 

Auxiliary Temperature Sensor Input 1 – Voltage Above Normal, or Shorted to High Source. High signal voltage or open circuit detected at the OEM auxiliary temperature circuit.

None on performance.

Auxiliary Temperature Sensor Input 1 Circuit
SMALL | MEDIUM | LARGE

Circuit Description

The OEM has the option of wiring a temperature sensor input to the Cummins ECM. A specific calibration is then created to recognize this temperature sensor input.

Component Location

The OEM temperature sensor input will vary depending on application. Refer to the OEM troubleshooting manual for sensor location.

Shop Talk

Possible causes of this fault code include:

  • Open return circuit in the harness, connectors, or sensor
  • Open signal circuit or shorted to a voltage source.

Refer to Troubleshooting Fault Code t05-293

Last Modified:  08-Jul-2010