CM850 Electronic Control System – FAULT CODE 298

Auxiliary Pressure Sensor Input 1 Circuit – Voltage Below Normal, or Shorted to Low Source


Overview

CODE REASON EFFECT
Fault Code: 298
PID: P223
SPN: 1388
FMI: 4
LAMP: Amber
SRT: 

Auxiliary Pressure Sensor Input 1 Circuit – Voltage Below Normal, or Shorted to Low Source. Low signal voltage or open circuit detected at the OEM pressure circuit.

None on performance.

Auxiliary Pressure Sensor Input One Circuit
SMALL | MEDIUM | LARGE

Circuit Description

The OEM has the option of wiring a pressure sensor input to the Cummins ECM. A specific calibration is then created to recognize this pressure sensor input.

Component Location

The OEM pressure sensor input will vary depending on application. Refer to the OEM troubleshooting manual for sensor location.

Shop Talk

Possible causes of this fault code include:

  • Signal circuit open or shorted to ground in the OEM harness or sensor.
  • Supply line open or shorted to ground.

Refer to Troubleshooting Fault Code t05-298