ISC, ISCe, QSC8.3, ISL, ISLe3, ISLe4 and QSL9 Engines – 009-055   Refrigerant Compressor Mounting Bracket

View Related Topic


Preparatory Steps

TOC

 WARNING 

Batteries can emit explosive gases. To reduce the possibility of personal injury, always ventilate the compartment before servicing the batteries. To reduce the possibility of arcing, remove the negative (-) battery cable first and attach the negative (-) battery cable last.

SMALL | MEDIUM | LARGE

Remove

TOC

Remove the refrigerant compressor bracket mounting capscrews and bracket.

SMALL | MEDIUM | LARGE
   

Clean and Inspect for Reuse

TOC

 WARNING 

When using a steam cleaner, wear safety glasses or a face shield, as well as protective clothing. Hot steam can cause serious personal injury.
 WARNING 

When using solvents, acids, or alkaline materials for cleaning, follow the manufacturer’s recommendations for use. Wear goggles and protective clothing to reduce the possibility of personal injury.
 WARNING 

Wear appropriate eye and face protection when using compressed air. Flying debris and dirt can cause personal injury.

Use steam or solvent to clean the refrigerant compressor mounting brackets.

Dry with compressed air.

Inspect the refrigerant compressor mounting brackets for cracks or damage.

If cracks are found on the refrigerant compressor mounting brackets, they
must be replaced.

SMALL | MEDIUM | LARGE
   

Install

TOC

Install the refrigerant compressor mounting bracket and bracket mounting capscrews.

Torque Value:  46  n.m  [34 ft-lb]

NOTE: Due to the availability of different bracket configurations, this procedure is meant to be generic. Note any knife edges or alignment pins on the bracket that need to be used and make sure the mating or alignment features are free from debris.

SMALL | MEDIUM | LARGE
   