ISC, ISCe, QSC8.3, ISL, ISLe3, ISLe4 and QSL9 Engines – 013-007   Batteries

Table of Contents

Initial Check

Initial Check

TOC

 WARNING 

Acid is extremely dangerous and can damage the machinery and can also cause serious burns. Always provide a tank of strong soda water as a neutralizing agent when servicing the batteries. Wear goggles and protective clothing to reduce the possibility of serious personal injury.

If conventional batteries are used, remove the cell caps or covers and check the electrolyte level.

NOTE: Maintenance-free batteries are sealed and do not require the addition of water.

Fill each battery cell with distilled water. Refer to the battery manufacturer’s specifications.

SMALL | MEDIUM | LARGE


Use the Fleetguard® Refractometer, Part Number CC-2800, to check the specific gravity of the battery electrolyte.

Refer to the battery fluid column in the refractometer to determine the state-of-charge of each battery cell.

If water has been added to a dry cell, recharge the battery to mix the added water with the existing battery electrolyte to prevent inaccurate readings.

SMALL | MEDIUM | LARGE
   


Use a battery tester to test the output amperage of maintenance-free or conventional vent cap batteries.

If the output amperage is low, use a battery charger to charge the battery. Refer to the manufacturer’s instructions.

Replace the battery if it will not charge to the manufacturer’s specifications, or will not maintain a charge.

SMALL | MEDIUM | LARGE
Last Modified:  05-Jun-2003