Electrical Charging System Voltage – Data Valid but Below Normal Operational Range – Most Severe Level
|
Overview
CODE | REASON | EFFECT |
Fault Code: 598 PID: P167 SPN: 167 FMI: 1/1 LAMP: Red SRT: |
Electrical Charging System Voltage – Data Valid but Below Normal Operational Range – Most Severe Level. Very low battery voltage detected by the battery voltage monitor feature. |
Red lamp illuminated until very low battery voltage condition is corrected. |
ISX and ISM – ECM Power Supply Circuit
|
Circuit Description
The electronic control module (ECM) receives constant voltage from the batteries through the unswitched battery wires that are connected directly to the positive (+) battery post. The ECM receives switched battery input through the vehicle keyswitch wire when the vehicle keyswitch is turned on.
Component Location
The ECM is connected to the battery by the OEM harness. This direct link provides a constant power supply for the ECM. The location of the battery will vary with the OEM. Refer to the OEM manual for the battery location.
Conditions for Running the Diagnostics
This diagnostic runs continuously when the keyswitch is in the ON position.
Conditions for Setting the Fault Codes
The ECM detects that the battery voltage is less than 8 VDC.
Action Taken When the Fault Code is Active
- The ECM illuminates the red STOP ENGINE light immediately when the diagnostic runs and fails.
Conditions for Clearing the Fault Code
The ECM will turn off the red STOP ENGINE light when the diagnostic runs and passes.
Shop Talk
Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM. Refer to Procedure 019-032 (ECM Calibration Code) in Section 19 in the corresponding Troubleshooting and Repair Manual for the engine being serviced.
This fault code is part of the Battery Voltage Monitor feature. The ECM can increase idle speed and deactivate idle decrement switch if Idle Speedup is enabled. View the Battery Voltage Monitor feature settings using the INSITE™ electronic service tool. Disabling the Battery Voltage Monitor feature will also disable this fault code.
Make sure the ECM battery supply (+) is coming directly from the battery and not the starter.
Possible causes of this fault code:
- Undercharged batteries caused by a faulty alternator or regulator.
Refer to Troubleshooting Fault Code t05-598