CM2150 Electronic Control System – FAULT CODE 1676

Aftertreatment Exhaust Gas Temperature 2 – Data Erratic, Intermittent, or Incorrect


Overview

CODE REASON EFFECT
Fault Code: 1676
PID: None
SPN: 3249
FMI: 2/2
LAMP: Amber
SRT: 

Aftertreatment Exhaust Gas Temperature 2 – Data Erratic, Intermittent, or Incorrect. The aftertreatment diesel particulate filter inlet temperature sensor is not changing with engine operating conditions.

Active aftertreatment diesel particulate filter regeneration will be disabled.

ISB, ISC, and ISL with CM2150 – Aftertreatment Temperature Sensors
SMALL | MEDIUM | LARGE

Circuit Description

The aftertreatment temperature sensors are used by the electronic control module (ECM) to monitor the engine exhaust temperatures in the aftertreatment system. The aftertreatment temperature sensors are thermistors and change resistance based on the temperature being measured. The ECM provides a 5 volt reference voltage to the sensor. The ECM monitors the change in signal voltage and converts this to a temperature value.

When the exhaust gas temperature is low, the sensor or thermistor resistance is high. The ECM signal voltage only pulls down a small amount through the sensor to ground. Therefore, the ECM senses a high signal voltage or low temperature. When the exhaust gas temperature is high, the sensor resistance is low. The signal voltage pulls down a large amount. Therefore, the ECM senses a low signal voltage, or a high temperature.

Component Location

The aftertreatment diesel particulate filter inlet temperature sensor is located in the aftertreatment system. It is located at the outlet of the catalyst and before the aftertreatment particulate filter. Refer to the original equipment manufacturer (OEM) service manual.

Conditions for Running the Diagnostics

This diagnostic runs continuously when the engine is running and fuel injection into the aftertreatment system is not occurring.

Conditions for Setting the Fault Codes

The ECM detects that the aftertreatment diesel particulate filter inlet temperature sensor reading is not changing with engine operating conditions.

Action Taken When the Fault Code is Active

  • The ECM illuminates the amber CHECK ENGINE light immediately when the diagnostic runs and fails.
  • A default value for the aftertreatment diesel particulate filter inlet temperature reading is used.
  • Active aftertreatment diesel particulate filter regeneration will be disabled.

Conditions for Clearing the Fault Code

The ECM will turn off the amber CHECK ENGINE light immediately after the diagnostic runs and passes.

The engine must be running at any speed for 15 minutes and the aftertreatment diesel oxidation catalyst inlet temperature must be above 150°C [300°F] before the fault code will clear.

Shop Talk

Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe™ Online for applicable fixes to the calibration stored in the ECM. If necessary, calibrate the ECM. Refer to Procedure 019-032 (ECM Calibration Code) in Section 19.

Possible causes of this fault code include:

  • Stuck in-range aftertreatment diesel particulate filter inlet temperature sensor
  • High resistance in the aftertreatment diesel particulate filter inlet temperature sensor signal or return wires.

Refer to Troubleshooting Fault Code t05-1676

Last Modified:  20-Jul-2010