CM2150 Electronic Control System – Communication Error – Electronic Service Tool or Control Device

Symptom Tree  t016

This is symptom tree
Cause Correction

Error 5023: No connection to the ECM was established or detected

Refer to Procedure 019-472 in Section 19.

 

Error 5080: ECM is ROM Booted and must be recalibrated

Calibrate ECM with the appropriate ECM code. Refer to Procedure 019-032 in Section 19.

 

Error 5081: ECM is ROM Booted and must be recalibrated

Calibrate ECM with the appropriate ECM code. Refer to Procedure 019-032 in Section 19.

 

Error 5089: ECM is in an invalid state must be recalibrated

Power OFF for 30 seconds and reconnect. Refer to Procedure 019-472 in Section 19.

 

Error 5091: ECM is seeded and must be recalibrated

Calibrate ECM with the appropriate ECM code. Refer to Procedure 019-032 in Section 19.

 

Error 5092: INSITE™ electronic service tool has detected some ECM(s) can not operate and must be recalibrated. INSITE™ electronic service tool has detected the following ECM(s) are currently calibrated: ECM NAME, Service ECM Marketing Name, INSITE™ electronic service tool has detected some ECM(s) can not operate and must be calibrated. INSITE™ electronic service tool has detected the following ECM(s) have incompatible calibrations: ECM Name, Source Address

Recalibrate the ECM(s) that are not currently calibrated. Refer to Procedure 019-032 in Section 19.

 

Error 5200: Communication between the PC and the data link has been lost

Refer to Procedure 019-472 in Section 19.

 

Error 5201: Communication between the data link and the ECM has been lost

Refer to Procedure 019-472 in Section 19.

 

Error 5202: Communication between the data link and the ECM has been lost

Refer to Procedure 019-472 in Section 19.

 

Error 5204: Communication between the data link adapter and the ECM could not be established

Refer to Procedure 019-472 in Section 19.

 
Last Modified:  23-Jun-2010