Cummins N14 STC, Celect, Celect Plus – Service Manual 019-063   Internal Actuator Wiring Harness

Table of Contents

Install

Install

TOC

Push the internal actuator harness connector through the rocker lever housing until the locking tabs lock into position on the front of the rocker lever housing.

Connect the connector of the internal actuator harness to the connector of the external actuator harness.

SMALL | MEDIUM | LARGE


Connect the internal actuator harness to each of the six injector solenoids.

If the engine is equipped with a brake harness, connect the engine brake harness to the internal actuator harness and the engine brake solenoids.

SMALL | MEDIUM | LARGE
   


NOTE: If equipped with a 12-pin Metri-Pack™ keyed connector, align connector before the capscrew is tightened.

Install the locking capscrew with a Torx™ screwdriver.

Tighten the capscrew.

Torque Value:  1  n.m  [9 in-lb]

SMALL | MEDIUM | LARGE
   


 CAUTION 

Make sure the internal wiring harness is securely installed with the capscrews to the rocker lever housing. A loose internal wiring harness can be damaged by moving engine parts.

Install the five hold down capscrews securing the internal actuator harness to the rocker lever housing.

Torque Value:  20  n.m  [177 in-lb]

SMALL | MEDIUM | LARGE
Last Modified:  20-Mar-2012