Fault code information
1 trip MIL
3 drive cycle recovery
Readiness group – None
Freeze frame type – Comprehensive
Description of component(s)
The intercooler outlet temperature is measured before the EGR mixer.
Effect on the system:
* Monitors intercooler performance
Location of component(s)
Diagnostic condition
Sensor output voltage is greater than 4.865V
Set condition of fault code
The PCI detects sensor output voltage is too high (above 4.89 V).
Reset condition of fault code
This fault code will change to inactive immediately after the diagnostic runs and passes.
Electrical diagram(s)
Technical data
Component check, intercooler temperature sensor (F750)
Preparation
* Key off the ignition
* Disconnect connector F750
* Measure on component connector F750
Possible causes
* Faulty wiring
* Faulty connector
* Faulty sensor
Additional information
No additional information available.