Symptom Tree t049
| Cause | Correction |
|---|
|
Electronic fault codes active or high counts of inactive fault codes |
Refer to Section TF in the CELECT Plus™ Systems Troubleshooting and Repair Manual, Bulletin 3666130, or Section TF in the CELECT™ Systems Troubleshooting and Repair Manual, Bulletin 3666084. |
![]() |
|
Lubricating oil pressure is below specification |
Check the oil pressure. If the pressure is low, refer to Procedure 007-028 in Section 7. |
![]() |
|
Lubricating oil level is below specification |
Check the oil level. Verify the dipstick calibration and the oil pan capacity. Fill the system to the specified level. Refer to Procedure 007-009 and Procedure 007-025 in Section 7. |
![]() |
|
Lubricating oil is thin or diluted |
Refer to Procedure 007-037 in Section 7. If the oil pressure is low, refer to the Lubricating Oil Pressure Low troubleshooting symptom tree in Section TS. |
![]() |
|
Connecting rod capscrews are loose or not tightened correctly |
Check the torque on the connecting rod capscrews. Refer to Procedure 001-014 in Section 1. |
![]() |
|
Connecting rod bearings are damaged or worn, are not assembled correctly, or are the wrong bearings |
Inspect the connecting rod bearings. Refer to Procedure 001-014 in Section 1. |
![]() |
|
Connecting rod is bent or out of alignment |
Remove and inspect the connecting rods. Refer to Procedure 001-014 in Section 1. |
![]() |
|
Crankshaft journals are damaged or out of round |
Inspect the crankshaft journals. Refer to Procedure 001-016 in Section 1. |
![]() |