Centinel System – Repair Manual – 008-089   Fan Pulley

Remove

TOC

Industrial and Power Generation


Remove the fan and water pump belt. Refer to Procedure 008-003.

SMALL | MEDIUM | LARGE


Remove the alternator drive belt. Refer to Procedure 013-005.

SMALL | MEDIUM | LARGE
   


Remove six capscrews and the pulley from the fan support.

SMALL | MEDIUM | LARGE
   

Inspect for Reuse

TOC

Inspect the pulley for cracks, excessive wear in the belt grooves, or other damage.

SMALL | MEDIUM | LARGE
   

Install

TOC

Industrial and Power Generation


Install the fan pulley using six capscrews.

Tighten the capscrews in a star pattern.

Torque Value:  95  n.m  [70 ft-lb]

SMALL | MEDIUM | LARGE
   


Install the alternator drive belt. Refer to Procedure 013-005.

SMALL | MEDIUM | LARGE
   


Install the fan and water pump drive belt. Refer to Procedure 008-003.

SMALL | MEDIUM | LARGE
Last Modified:  26-Jun-2002