M11 Series – Service Manual – 007-012   Lubricating Oil Filter (Canister-Type)

Table of Contents

Leak Test

Leak Test

TOC

This procedure outlines the steps to isolate a centrifugal bypass filter when checking possible causes of high engine crankcase blowby.

Disconnect the air supply line from the centrifugal bypass filter assembly. Cap the end of the air supply line to prevent system air loss during test.

SMALL | MEDIUM | LARGE


Operate the engine and check the engine blowby. Refer to

Section 14.

If the blowby falls within the correct specifications, repair the centrifugal filter. Refer to the manufacturer’s guidelines for the correct procedure.

SMALL | MEDIUM | LARGE
   


Remove the cap from the air supply line.

Connect the air supply line (1) to the centrifugal bypass filter assembly.

SMALL | MEDIUM | LARGE
Last Modified:  07-May-2003