M11 Series – Service Manual – 008-021   Cooling System Precharge

General Information

TOC

Correct use of SCAs in conjunction with proper maintenance practices are needed to protect engines from cooling system problems. The system

must
be precharged with the correct number of units of SCA.

Cummins/Fleetguard® uses the SCA unit to define the required concentration level to protect against liner pitting.

 
SMALL | MEDIUM | LARGE

Factory Precharge Method

TOC

New engines have a DCA4 coolant filter installed at the factory that will precharge the cooling system to the correct SCA concentration of approximately 1.5 units per gallon.

 
SMALL | MEDIUM | LARGE
   

Customer Precharge Method

TOC

When coolant is replaced in the field, it

must be replaced with

fully formulated coolant or a 50/50 mixture of good-quality water and

fully formulated antifreeze and the correct service coolant filter. Refer to Specifications at the front of this section for correct requirements.

SMALL | MEDIUM | LARGE
Last Modified:  07-May-2003