On CELECT™ and CELECT™ Plus engines, all fan clutches can be controlled by the electronic control module (ECM). The ECM is programmed to turn the fan ON when 0 VDC (normally open switch) is applied to the fan clutch relay, and turn the fan OFF when 12 VDC (normally closed switch) is applied to the fan clutch relay.
The following fan clutch checks are for fan clutches wired to the electronic controlled fuel system. Refer to the vehicle manufacturer’s specifications to determine the installation of the fan clutch.
Remove the shutter stat from the thermostat housing, if equipped, and install a master temperature gauge that is known to be accurate. A thermocouple can be used.
If the vehicle is air-onditioned, make sure the air-conditioning is turned off to prevent continuous operation of the fan. When the coolant temperature reaches 96°C [205°F], check for fan engagement.
NOTE: The temperature given for fan engagement is for fans controlled by the ECM.
NOTE: Fan noise and airflow increase when the fan clutch engages.
must disengage before the coolant temperature drops to 93°C [200°F]. Cummins Engine Company, Inc. recommends the fan disengage at 3°C [6°F] below the temperature stamped on the fan temperature sensor.
NOTE: The temperature given for fan disengagement is for fans controlled by the ECM.
Hello, I'm Jack, a diesel engine fan and a blogger. I write about how to fix and improve diesel engines, from cars to trucks to generators. I also review the newest models and innovations in the diesel market. If you are interested in learning more about diesel engines, check out my blog and leave your feedback.