Symptom Tree t027
Cause | Correction |
---|
Crankcase ventilation system is plugged |
Check and clean the crankcase breather and vent tube. Refer to Procedure 003-001. |
Turbocharger oil seal is leaking |
Check the turbocharger compressor and turbine seals. Refer to Procedures 010-040 and 010-049. |
Air compressor is malfunctioning |
Isolate the air compressor by disconnecting the air inlet and outlet lines. Refer to Procedure 012-014. Check blowby. If blowby is within specifications, rebuild or replace the air compressor. |
Cylinder head valve guides are excessively worn |
Check the valve guides for wear. Replace the cylinder head if necessary. Refer to Procedure 002-004. |
Piston, piston rings, or cylinder liner is worn or damaged |
Inspect the air intake system for leads. Refer to Procedures 001-043, 001-047, and 001-028. |