Symptom Tree
Bulk oil supply is contaminated |
Check the bulk oil supply. Drain the oil and replace with noncontaminated oil. Clean the Eliminator oil filter centrifuge. Refer to Procedure 007-002 (Lubricating Oil and Filters) in Section 4. |
Lubricating oil does not meet specifications for operating conditions |
Change the oil and filters. Refer to Procedure 007-013 (Lubricating Oil Filter – Spin-on) in Section 4. |
Lubricating oil drain interval is excessive |
Verify the correct lubricating oil drain interval. Refer to Procedure 102-002 (Maintenance Schedule) in Section 2 for oil drain interval. |
Fuel grade is not correct for the application or the fuel quality is poor |
Operate the engine from a tank of high-quality fuel. Refer to Procedure 018-002 (Fuel Recommendations and Specifications) in Section V. |
Coolant temperature is below specification |
Refer to the Coolant Temperature Below Normal symptom tree. |
Crankcase ventilation system is plugged |
Check and clean the crankcase breather and vent tube. Refer to Procedure 003-018 (Crankcase Breather Tube) in Section 5. |
Contact a Cummins Authorized Repair Facility |