Centinel™ Control Module Error
|
Overview
| CODE | REASON | EFFECT |
| Fault Code: 111 PID: FMI: LAMP: None SRT: |
Centinel™ Control Module Error. An error occurred during the diagnostic test of the Centinel™ control module internal hardware. |
The Centinel™ system will not operate properly. |
|
Centinel™ Control Module |
![]() |
Circuit Description
The Centinel™ control module is a computer that is responsible for Centinel™ system control and diagnostics.
Component Location
Heavy-duty: The Centinel™ control module is located on the Centinel™
system make-up oil tank.
High-horsepower: The Centinel™
control module is located on the Centinel™ system oil control valve mounting bracket.
Shop Talk
This fault code can be caused only by an internal Centinel™
control module problem. Only on high-horsepower should you try to clear a fault code with use of the service plug. Repairs are not possible for the Centinel™ control module.
Cautions and Warnings
CAUTION ![]() To avoid damaging a new Centinel™ control module, all other active fault codes must be investigated prior to replacing the Centinel™ control module. |
Troubleshooting Steps
| STEPS | SPECIFICATIONS | |
|---|---|---|
| STEP 1. | Check the fault codes. | |
| STEP 1A. Read the fault codes. | Fault Code 111 inactive | |
| STEP 1B. Check the fault codes. | Complete | |
Guided Step 1 – Check the fault codes. (This step is for high-horsepower only. For heavy-duty, continue to Step 1B.)
CAUTION ![]() To avoid damaging a new Centinel™ control module, all other active fault codes must be investigated prior to replacing the Centinel™ control module. |
| Guided Step 1A – Read the fault codes. | |
|---|---|
Conditions
Action
|
|
| OK | NOT OK |
|
Fault Code 111 inactive |
High-horsepower only: Clear the fault codes with the service plug. Refer to Procedure 209-001. |
CAUTION ![]() To avoid damaging a new Centinel™ control module, all other active fault codes must be investigated prior to replacing the Centinel™ control module. |
| Guided Step 1B – Check the fault codes. | |
|---|---|
Conditions
Action
|
|
| OK | NOT OK |
|
Fault Code 111 inactive |
Replace the Centinel™ control module Refer to Procedure 019-130. |

CAUTION