Symptom Tree t103-2
Cause | Correction |
---|
Centinel makeup tank is empty |
Check makeup tank oil level daily. Add oil if necessary. |
![]() |
Lubricating oil lines are bent or crimped |
Check to see that all oil lines are free of crimps and sharp bends. |
![]() |
Lubricating oil lines leak oil |
Check all oil lines and fittings for leaks. Tighten loose fittings and replace leaking oil lines if necessary. |
![]() |
Oil temperature never sensed above 125 degrees Fahrenheit. |
ECM will not cycle valve below 125 degree Fahrenheit. Confirm proper operation of oil pressure temperature sensor. |
![]() |
Oil rifle supply never exceeds 20 psi |
Check for restriction from the oil rifle to the Centinel™ valve solenoid. |
![]() |
Make-up system not primed |
Perform priming procedure. Refer to the Master Repair Manual Centinel™, Bulletin 3666231. |
![]() |
Internal Centinel™ valve failure |
Replace Centinel™ valve. Refer to the Master Repair Manual Centinel™, Bulletin 3666231. |