ISM, ISMe, and QSM11 – Oil Pan Level Incorrect – Low (Centinel)

Symptom Tree  108-10

This is symptom tree 108-10
Cause Correction

OEM starter interlock devices engaged

Check the starter interlock devices. Refer to the OEM service manual.

 

Makeup tank vent clogged

Check makeup tank vent. Clean if necessary.

 

Lubricating oil hoses are bent or crimped

Check to see that all oil lines are free of crimps and sharp bends.

 

Lubricating oil hoses leak oil

Check all hose fittings for leaks. Tighten loose fittings and replace leaking oil hoses if necessary.

 

Make-up system not primed

Perform priming procedure. Refer to the Master Repair Manual Centinel™, Bulletin 3666231.

 

Internal control valve failure

Replace the control valve. Refer to the Master Repair Manual Centinel™, Bulletin 3666231.

 