ISB/ISBe Series Engines – FAULT CODE 386

Sensor Supply A – High Voltage


Overview

CODE REASON EFFECT
Fault Code: 386
PID: S232
SPN: 1079
FMI: 3
LAMP: Yellow
SRT: 

High voltage detected on the electronic control module (ECM) voltage supply wire to the intake manifold pressure, OEM pressure, coolant level, and remote accelerator sensors.

Default values used for sensors connected to the +5-VDC supply and possible default to idle speed. Lower power can occur because fueling defaulted to no-boost fueling. Also, possible loss of engine protection for the sensors.

Sensor Supply A – High Voltage
SMALL | MEDIUM | LARGE

Circuit Description

The ECM supplies each of these sensors with positive +5 VDC. If the supply wire to any sensor is damaged, the sensor will not work correctly.

Component Location

There are four components involved in the sensor voltage supply: Intake manifold pressure/temperature, OEM pressure, coolant level, and remote accelerator sensors. See Section E for component location.

Shop Talk

High voltage on the sensor +5-VDC supply wire will be caused by a short circuit to battery of the supply wire or a short circuit between an actuator wire and the supply wire.

Refer to Troubleshooting Fault Code t05-386

Last Modified:  26-Oct-2010