Leaking Throttle Plate
|
Overview
| CODE | REASON | EFFECT |
| Fault Code: 2189 PID: S58 SPN: 698 FMI: 7 LAMP: Amber SRT: |
Throttle actuator leaking. |
The engine will idle above 900 rpm. |
|
Throttle Actuator Circuit |
![]() |
Circuit Description
The electronic control module (ECM) controls the throttle actuator; it is both an input and output device.
Component Location
The throttle actuator is located after the fuel housing and before the intake manifold cover.
Shop Talk
The throttle actuator used for the Gas Plus engines is pulse-width modulated. Leaks, especially missing pipe and cap plugs, after the throttle actuator can also cause this fault. Excessive backfire can cause a bent throttle plate.
Troubleshooting Steps
| STEPS | SPECIFICATIONS | |
|---|---|---|
| STEP 1. | Check the engine idle speed. | |
| STEP 1A. Check the engine idle speed using INSITE™ electronic service tool. | 700 to 900 rpm? | |
| STEP 1B. Check for air leaks in the air intake system. | Air leaks? | |
| STEP 1C. Check the throttle actuator. | Did actuator pass the test? | |
| STEP 2. | Clear the fault codes. | |
| STEP 2A. Disable the fault code. | Fault Code 2189 inactive? | |
| STEP 2B. Clear the inactive fault codes. | All fault codes cleared? | |
Guided Step 1 – Check the engine idle speed.
| Guided Step 1A – Check the engine idle speed using INSITE™. | |
|---|---|
Conditions
Action
|
|
|
700 to 900 rpm? |
|
| YES | NO |
| No Repair | No Repair |
| Guided Step 1B – Check for air leaks in the air intake system. | |
|---|---|
Conditions
Action
|
|
|
Air Leaks? |
|
| YES | NO |
|
Locate all damaged gaskets or parts and replace accordingly. |
No Repair |
| Guided Step 1C – Check the throttle actuator | |
|---|---|
Conditions
Action
|
|
|
Did actuator pass test? |
|
| YES | NO |
| No Repair |
Replace the throttle actuator. Refer to Procedure 019-097. |
Guided Step 2 – Clear the fault codes.
| Guided Step 2A – Disable the fault code. | |
|---|---|
Conditions
Action
|
|
|
Fault Code 2189 inactive? |
|
| YES | NO |
| No Repair |
Troubleshooting procedures need to be repeated from the beginning. |
| Guided Step 2B – Clear the inactive fault codes. | |
|---|---|
Conditions
Action
|
|
|
All fault codes cleared? |
|
| YES | NO |
| No Repair |
Troubleshoot any remaining active fault codes. |
|
Repair complete
|
Appropriate troubleshooting charts
|