CM850 Electronic Control System – 019-059   Intake Manifold Air Temperature Sensor

Table of Contents

Remove
Inspect for Reuse
Install

Remove

TOC

Disconnect the wiring harness connector from the sensor.

Remove the intake manifold air temperature sensor from the intake manifold cover.

SMALL | MEDIUM | LARGE

Inspect for Reuse

TOC

Use the electronic service tool to monitor the air temperature sensor.

Perform a rationale check to see if the sensor is reading an appropriate reading.

 
SMALL | MEDIUM | LARGE
   

Install

TOC

Install the sensor and tighten the capscrew.

Torque Value:  23  n.m  [17 ft-lb]

Connect the wiring harness connector to the sensor.

Turn the keyswitch ON.

Use the electronic service tool to monitor the temperature sensor to make sure it is working correctly.

Refer to the resistance charts on the wiring diagram for sensor resistance values.

SMALL | MEDIUM | LARGE
Last Modified:  13-May-2003