CM850 Electronic Control System – FAULT CODE 2555

Intake Air Heater #1 Circuit – Voltage Above Normal or Shorted to High Source


Overview

Intake Air Heater #1 Circuit – Voltage Above Normal or Shorted to High Source

CODE REASON EFFECT
Fault Code: 2555
PID: S070
SPN: 729
FMI: 3
LAMP: Amber
SRT: 

Intake Air Heater #1 Circuit – Voltage Above Normal or Shorted to High Source. High voltage detected at the intake air heater signal circuit.

The intake air heaters may be ON or OFF all the time.

Intake Air Heater #1 Circuit
SMALL | MEDIUM | LARGE

Circuit Description

The intake air heater improves starting and white smoke control in cold ambient conditions. The ECM controls relays that switch power to the intake air heater. 12-volt systems will have two relays while 24-volt systems only require one relay.

Component Location

The intake air heater is located at the air inlet connection into the intake manifold. The location of the intake air heater relays will vary by OEM. Refer to Procedure 100-002 in Section E.

Shop Talk

Possible causes of this fault code include:

  • Intake air heater relay signal wire not connected to the relay
  • Intake air heater relay return wire not connected to the relay
  • Open circuit in the intake air heater relay signal wire
  • Open circuit in the intake air heater relay return wire
  • Intake air heater signal wire shorted to a voltage source.

Refer to Troubleshooting Fault Code t05-2555

Last Modified:  08-Jul-2010