Remove the rocker lever cover. Refer to Procedure 003-011 in the ISM, ISMe and QSM11 Service Manual, Bulletin 3666322, or the Signature, ISX and QSX15 Service Manual, Bulletin 3666239.
Replace or repair the internal actuator harness if there is an open circuit or a short circuit found under the protective covering of the harness body.
Clean the connector bore in the rocker lever housing.
Push the internal actuator harness connector through the rocker lever housing until the locking tabs lock into position on the front of the rocker lever housing.
Install the rocker lever cover. Refer to Procedure 003-011 in the ISM, ISMe and QSM11 Service Manual, Bulletin 3666322, or the Signature, ISX and QSX15 Service Manual, Bulletin 3666239.
Hello, I'm Jack, a diesel engine fan and a blogger. I write about how to fix and improve diesel engines, from cars to trucks to generators. I also review the newest models and innovations in the diesel market. If you are interested in learning more about diesel engines, check out my blog and leave your feedback.