Batteries can emit explosive gases. To reduce the possibility of personal injury, always ventilate the compartment before servicing the batteries. To reduce the possibility of arcing, remove the negative (-) battery cable first and attach the negative (-) battery cable last.
Use checking fixture, Part Number ST-561, and mandrel set, Part Number 3376690, to inspect the bend and twist of the connecting rod.
Calibrate the checking fixture with a new rod that has be measured for the correct center to center length, 217.975 to 218.025 mm [8.5817 to 8.5836 in].
Check the dial indicators for zero (0) position again.
If the dial indicators show any change from zero (0), adjust the dials to half the indicated reading.
The fixture is now calibrated to allow the connecting rod to be installed into the fixture in either direction and the dials will indicate an equal defection on either side of the zero (0).
Batteries can emit explosive gases. To reduce the possibility of personal injury, always ventilate the compartment before servicing the batteries. To reduce the possibility of arcing, remove the negative (-) battery cable first and attach the negative (-) battery cable last.
Hello, I'm Jack, a diesel engine fan and a blogger. I write about how to fix and improve diesel engines, from cars to trucks to generators. I also review the newest models and innovations in the diesel market. If you are interested in learning more about diesel engines, check out my blog and leave your feedback.